Suntube IV Clearances to Combustibles
MBTUH INPUT NAT OR LP
40
45,50
55,60
65,70
75,80
85

65,70
75,80
85,90,95

100
105,110
115,120
125
130,135
140,145
150
155,160
165,170
175
180,185
190,195
200

AVAILABLE TUBE LENGTH (FEET)
10’,15’
20’
20'
20'
20'‡
25'‡ §
30',35'§
40'
30',35'§
40' 45'§
50'
40' 45'§
50'
40' 45'§
50'

40' 45'§
50' 55'§
60', 65'§
70'

50' 55'§
60', 65'§
70'
50' 55'§
60', 65'§
70'
CLEARANCES* (INCHES)
TOP OF REFLECTOR
12”
12”
12”
12”
12”
12”
12”
12”
12”
12”
12”
 
FRONT OF REFLECTOR
 MOUNTED 0
40”
40”
50”
24"
24"
24"
32"
48"
48"
58"
68"
 MOUNTED 1 to 30
40”
40”
50”
24"
24"
24"
32"
48"
48"
58"
68"
 MOUNTED 31 to 45
40”
40”
50”
x
x
x
x
70"
70"
80"
90"
 
REAR OF REFLECTOR
 MOUNTED 0
40”
40”
50”
24"
24"
24"
32"
48"
48"
58"
68"
 MOUNTED 1 to 30
40”
40”
50”
24"
24"
24"
32"
48"
48"
58"
68"
 MOUNTED 31 to 45
12”
12”
12”
x
x
x
x
12”
12”
12”
12”
 
BELOW REFLECTOR
40”
40”
50”
60”
60”
60”
72”
82”
82”
92”
92”
‡ Natural gas Only      § Not Available in U-Tube configuration     * For all systems: 12" from burner end and 68" from U-Bend

System Information

Manifold Operating Pressure

Natural Gas
& LP/Propane: 3.5" WC

Minimum Inlet Pressure
Natural Gas:
40-125 MBTUH 6" WC
130-200 MBTUH 7"WC

LP/Propane:
All MBTUH 11" WC

1/2"FPT Gas Inlet

Electrical Rating:

120 VAC-60 Hz-1 Phase
Solaronics U-Tube heaters maintain employee comfort in NJ plant.
Ask for Case History 62.
Warranty : 10 year limited warranty on All combustion and heat exchanger tubes, 10 year limited warranty on Burner Core, 2 year limited warranty on All Burner Controls


Leader in Quality Gas-Fired Infra-Red Products

Solaronics, Inc. • P.O. Box 80217 • 704 Woodward Ave. • Rochester, MI 48308-0217
Phone: (800) 223-5335 • Phone: (248) 651-5333 • Fax: (248) 651-0357