solaronics gas heater







Products
menu
menu
menu
menu
 
GQ Clearances to Combustibles
MBTUH INPUT NAT OR LP
40
45,50
55,60
65,70
75,80
85

65,70
75,80
85,90,95

100
105,110
115,120
125
130,135
140,145
150
155,160
165,170
175
180,185
190,195
200

AVAILABLE TUBE LENGTH (FEET)
10’,15’
20’
20'
20'
20'‡
25'‡ §
30',35'§
40'
30',35'§
40' 45'§
50'
40' 45'§
50'
40' 45'§
50'

40' 45'§
50' 55'§
60', 65'§
70'

50' 55'§
60', 65'§
70'
50' 55'§
60', 65'§
70'
CLEARANCES* (INCHES)
TOP OF REFLECTOR
12”
12”
12”
12”
12”
12”
12”
12”
12”
12”
12”
 
FRONT OF REFLECTOR
 MOUNTED 0
40”
40”
50”
24"
24"
24"
32"
48"
48"
58"
68"
 MOUNTED 1 to 30
40”
40”
50”
24"
24"
24"
32"
48"
48"
58"
68"
 MOUNTED 31 to 45
40”
40”
50”
x
x
x
x
70"
70"
80"
90"
 
REAR OF REFLECTOR
 MOUNTED 0
40”
40”
50”
24"
24"
24"
32"
48"
48"
58"
68"
 MOUNTED 1 to 30
40”
40”
50”
24"
24"
24"
32"
48"
48"
58"
68"
 MOUNTED 31 to 45
12”
12”
12”
x
x
x
x
12”
12”
12”
12”
 
BELOW REFLECTOR
40”
40”
50”
60”
60”
60”
72”
82”
82”
92”
92”
‡ Natural gas Only      § Not Available in U-Tube configuration     * For all systems: 12" from burner end and 68" from U-Bend
System Information

Manifold Operating Pressure
Natural Gas & LP/Propane:
40-100 MBTUH 3.5" WC
105-200 MBTUH 5" WC

Minimum Inlet Pressure

Natural Gas:
40-125 MBTUH 6" WC
130-200 MBTUH 7" WC

LP/Propane:
All MBTUH 11" WC

1/2" FPT Gas Inlet

Electrical Rating:

120 VAC-60 Hz-1 Phase

Direct the heat where you want it. Each 5' or 10' reflector rotates independently from 0° to 45°.

Superior Reflectional Efficiency of 91.7%. 33 of 36 infra-red rays are directed to the floor, not back on the tube.

APPLICATIONS
  • Aircraft Hangers
  • Assembly Rooms
  • Auditoriums
  • Auto Dealerships
  • Body Shops
  • Auto Service
  • Car Dealers
  • Car Washes
  • Factories
  • Farm Buildings
  • Fire Stations
  • Garages
  • Green Houses
  • Gymnasiums
  • Hangars
  • Indoor Tennis Courts
  • Loading Docks
  • Maintenance Facilities
  • Manufacturing Plants
  • Parking Ramps
  • Saves Up To 75% In Energy Costs
  • Skating Rinks
  • Sports Facilities
  • Truck Terminals
  • Showrooms
  • Warehouses
SUNTUBE
  • A.G.A. And C.G.A. Design Certified.
  • Minimum inlet pressure: Nat. gas for 40 to 125 MBTUH - 6" WC Nat. Gas for 130 to 200 MBTUH - 7" WC LP gas - 11" WC
  • Maximum inlet pressure: 14" WC.
  • 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 155, 160, 165, 170, 175, 180, 185, 190, 195 or 200 MBTUH input.
  • 10', 15', 20', 25', 30', 35', 40', 45', 50', 55', 60', 65' or 70' radiant tube lengths.
  • Straight, L, Z, U or compact U configurations.
  • Vented or unvented exhaust.
  • Indoor or outdoor combustion air.
  • 35' maximum length of vented exhaust for 40 to 125 MBTUH or 40' for 130 to 200 MBTUH.
  • 35' maximum length of outside combustion air for 40 to 125 MBTUH or 40' for 130 to 200 MBTUH.
  • Dry-no condensation of flue products during steady-state operations.
  • Direct spark ignition - 100% safety shut-off.
  • Positive pressure blower with pre-purge cycle.
  • Simple chain hanging arrangement.
  • Pre-assembled in 5' or 10' sections.
BURNER
  • 120 VAC - 1 - Phase - 60 Hz.
  • 1.47 full load amps for 40 to 125 MBTUH.
  • 1.33 full load amps for 130 to 200 MBTUH.
  • 1/25 HP blower motor - 148 CFM free air for 40 to 125 MBTUH or 138 CFM free air for 130 to 200 MBTUH.
  • 1/2" FPT gas inlet.
  • Electronic flame monitoring for safety.
  • 3-prong 36" electric power cord - 16/3 SJT.
  • Air pressure switch for air flow safety.
  • Three system validation lights for safety.
  • Spark and flame observation window.
  • Fixed combustion air orifice.
  • 4" O.D. combustion air inlet collar - standard.
REFLECTORS
  • 24 ga. (0.024") Mirror Brite Finish Aluminum.
  • 1.98 sq. ft. reflective area per linear foot.
  • Rotatable 0 degrees to 30 degrees for 75 to 125 MBTUH or 0 degrees to 45 degrees for 40 to 60 and 130 to 200 MBTUH (patent #4319125).
  • Scientifically designed for optimum dispersion.
  • Snap-in or snap-out without tools for easy removal.
  • 15 3/4" wide x 6 1/2" high x 5' or 10' long.
  • Reflectional efficiency 91.7%.
COMBUSTION CHAMBER
  • 4" O.D. tubing x 10' long.
  • 14 Ga. (0.083") Aluma Therm (Aluminized Titanium Steel) for 65-100 MBTUH.
  • 14 Ga. (0.083") Aluma Therm (Aluminized Titanium Steel) Painted black with high emissivity paint for 105-200 MBTUH.
  • 12 Ga. (0.109") black steel for 40 to 60 MBTUH.
  • 4.53 lbs. Per linear foot.
  • 1.052 sq. Ft. of radiant surface per linear foot.
HEAT EXCHANGER (S)
  • 4" O.D. Tubing x 5' or 10' long.
  • 12 Ga. (0.109") black steel.
  • 4.53 lbs. Per linear foot.
  • 1.052 sq. Ft. Of radiant surface per linear foot.
  • Wave formed turbulator for increased efficiency.
TUBE CLAMP ASSEMBLY
  • 4" I.D. x 8" long.
  • Compression coupling design.
  • 2 layers of 18 Ga. (0.052") aluminized steel.
  • Inner sleeve with precision-meshing teeth for uniform draw and pressure.
  • (4) 5/8" zinc plated carriage bolts.
  • Turnbuckle #5 malleable iron - 5/8"eye to eye with locking nuts. Pull tested to 720 lbs.
  • Sliding hanger for expansion & contraction.
WARRANTY
  • Limited warranty covering the burner controls, components, and hardware for a period of two (2) years, and the combustion chamber, heat exchangers, and burner core for a period of ten (10) years.


Suntube GQSuntube IVSuntube Stainless Steel
GQ Submittal Data • GQ Clearance to Combustibles
top of this page

Leader in Quality Gas-Fired Infra-Red Products

Solaronics, Inc. • P.O. Box 80217 • 704 Woodward Ave. • Rochester, MI 48308-0217
Phone: (800) 223-5335 • Phone: (248) 651-5333 • Fax: (248) 651-0357