solaronics gas heater







Products
menu
menu
menu
menu

 
Stainless Steel Clearances to Combustibles
MBTUH INPUT NAT OR LP
40
45,50
55,60
65,70
75,80
85

65,70
75,80
85,90,95

100
105,110
115,120
125
130,135
140,145
150
155,160
165,170
175
180,185
190,195
200

AVAILABLE TUBE LENGTH (FEET)
10’,15’
20’
20'
20'
20'‡
25'‡ §
30',35'§
40'
30',35'§
40' 45'§
50'
40' 45'§
50'
40' 45'§
50'

40' 45'§
50' 55'§
60', 65'§
70'

50' 55'§
60', 65'§
70'
50' 55'§
60', 65'§
70'
CLEARANCES* (INCHES)
TOP OF REFLECTOR
12”
12”
12”
12”
12”
12”
12”
12”
12”
12”
12”
 
FRONT OF REFLECTOR
 MOUNTED 0
40”
40”
50”
24"
24"
24"
32"
48"
48"
58"
68"
 MOUNTED 1 to 30
40”
40”
50”
24"
24"
24"
32"
48"
48"
58"
68"
 MOUNTED 31 to 45
40”
40”
50”
x
x
x
x
70"
70"
80"
90"
 
REAR OF REFLECTOR
 MOUNTED 0
40”
40”
50”
24"
24"
24"
32"
48"
48"
58"
68"
 MOUNTED 1 to 30
40”
40”
50”
24"
24"
24"
32"
48"
48"
58"
68"
 MOUNTED 31 to 45
12”
12”
12”
x
x
x
x
12”
12”
12”
12”
 
BELOW REFLECTOR
40”
40”
50”
60”
60”
60”
72”
82”
82”
92”
92”
System Information

Manifold Operating Pressure

Natural Gas & LP/Propane:
40-105 MBTUH 6" WC
130-200 MBTUH 7"WC

Minimum Inlet Pressure
Natural Gas:
40-125 MBTUH 6" WC
130-200 MBTUH 7"WC

LP/Propane:
All MBTUH 11" WC

1/2"FPT Gas Inlet

Electrical Rating:

120 VAC-60 Hz-1 Phase Blower:
1/24 h.p. motor 1.30 max. amp.
draw@ 138 cfm/free air

Vent Size:

4" I.D.